Systxccitc01 b has been discontinued - Well, the recommend their $600 thermostat the most, which allows CFM control, but that's out of the budget. My AC is this Infinity unit with 2-stages. My furnace is ( edit: I previously linked to the wrong unit) this Infinity unit. All things the same, I prefer Nest over Ecobee. The only Nest that works with my system's wiring is the Learning ...

 
Feb 20, 2020 · systxccrct01 (CAT-5-B-SAM) – Ethernet Remote Access Module Connects an Infinity system to network via ethernet for remote Access in-lieu of a wifi thermostat. Can be used in-lieu of a smart thermostat to allow a user to change climate settings remotely. . Wolf knight

Old Post, but here is an update - Carrier has release a new firmware 4.23, and they have updated the Home app (at least in Android) and this seems to have resolved the connectivity issue. I can now get a live connection to the thermostat, and changes made on the app reflect on the thermostat almost immediately. Vast improvement. 1.Our Infinity Remote Access Touch Control programmable thermostat (SYSTXCCITC01-B) offers versatility and beauty with a slim wall-hugging design, and intelligent comfort control. update to this issue (I was having it too) - Carrier has release 4.23 for the thermostat, and on Android they have updated the Home app. This has resolved all these issues. Now my app connects almost immediately, and the changes on the app reflect almost instantaneously on it. Took carrier long enough.I've learned it's better to ask first. Thanks very much for the reply! I can confirm that these controls are interchangeable. I've installed a Carrier Infinity Touch SYSTXCCITC01-B with a Carrier FE4AN Fan Coil and a Bryant 280ANV Heat Pump and they all get along just fine.Carrier SYSTXCCITC01-B Installation Instructions. Rating 2.5 (votes: 4) Description.The Infinity controller would allow for a bit more comfort with the 3 stages of heat and it's dehumidifying capabilities. Also, if your humidifier is currently controlled by the Infinity, you might have to move it to it's own stand alone humidistat and do some re-wiring to make it work.update to this issue (I was having it too) - Carrier has release 4.23 for the thermostat, and on Android they have updated the Home app. This has resolved all these issues. Now my app connects almost immediately, and the changes on the app reflect almost instantaneously on it. Took carrier long enough.Yes, using systxccitc01-b + Infinitude + the custom HA climate component, and the integration works. Only thing of note is that adjustments made on the thermostat itself occasionally get overwritten by Infinitude, so my family uses exclusively HA or Google home to make adjustments now, which is better than the interface on that POS anyhow.These systems have a feature called TrueSense filt er detection. This feature reads the change in static pressure caused by the filter accumulating di rt. At 1:00 pm each day the system will take a reading and record the change in static pressure. The clean or replace filter message will pop up when the filter is full.SYSTXCCICF01---B, SYSTXCCWIF01---B Infinityr System Control Owner’s Manual A170203 A180218C NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Occupancy sensing is only available with Series B Infinity System Controls.Find helpful customer reviews and review ratings for Carrier Infinity SYSTXCCITC01-B Touch Screen Programmable WiFi Thermostat - BLACK at Amazon.com. Read honest and unbiased product reviews from our users. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings and cautions included in literature and attached to the unit. Consult local building codes and the current edition of the National Electrical Code (NEC) NFPA 70. In Canada, refer to the current editions of the Canadian Electrical Code CSA C22.1. Jun 21, 2022 · SYSTXCCITC01-C The series C software is available by Over The Air (OTA) only. Note: This software is for the Series C controls only. The Series A or B controls cannot use Infinity ® System Control - SYSTXCCITC01-B. The Infinity ® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy sensing capabilities and built-in smarts, the Infinity System Control puts you in command of comfort and energy ... Oct 25, 2021 · I have a SYSTXCCUID01-B Version 14 Carrier Infinity System Thermostat that is malfunctioning and read you recommended the SYSTXCCITC01-B as a compatible replacement from supplyhouse.com. My question i … read more Apr 5, 2023 · Carrier Infinity Touch circus continues SYSTXCCITC01-B off calibration issue. Ok, I have had my share of fun with Carrier infinity touch thermostats but I had a call back on a touch B where the temperature is off by 4 degrees. I verified temps and the unit is indeed showing 4 degrees colder than room temp. If you have a newer touch thermostat, in my case, circa 2017 SYSTXCCITC01-B (which retails for close to $1000, though can find cheaper on eBay like I did), you CAN NOT get this working with Home Assistant at this time. Infinitive will NOT work with this model thermostat.SYSTXCCITC01---B, SYSTXCCWIC01---B, SYSTXCCICF01---B, SYSTXCCWIF01---B Infinityr System Control Owner’s Manual A170203 A180218C NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Sep 1, 2019 · Carrier Infinity SYSTXCCITC01-B compatibility with older Infinity Systems. I have a circa 2007 Carrier Infinity System (communicating) and would like to know if I can upgrade to the SYSTXCCITC01-B wifi thermostats. My outside unit is the 24ANA7 and the furnace is the 58CVA110. I have the old SYSTXCCUID01-B communicating thermostat. About The Carrier Infinity SYSTXCCITC01-B is part of the Thermostats test program at Consumer Reports. In our lab tests, Smart Thermostats models like the Infinity SYSTXCCITC01-B are...SYSTXCCITC01-C, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 Model Number Nomenclature A170101 Fig. 1 – Unit Dimensions SYSTX Product Type Infinity® System ITC 01 Brand / Product CC = Carrier XX or NN ... $99900 FREE Returns FREE delivery Saturday, September 9 Or fastest delivery Wednesday, September 6. Order within 22 hrs 54 mins Select delivery location Qty: 1 Buy Now Payment Secure transaction Ships from Amazon Sold by Returns Eligible for Return, Refund or Replacement within 30 days of receipt Support Product support included PaymentOld Post, but here is an update - Carrier has release a new firmware 4.23, and they have updated the Home app (at least in Android) and this seems to have resolved the connectivity issue. I can now get a live connection to the thermostat, and changes made on the app reflect on the thermostat almost immediately. Vast improvement. 1.Your Savings: $1,479.88 (52%) Carrier Products SYSTXCCITC01-B Infinity WiFi Touch Screen *** This Item is a direct current replacement for SYSTXCCUID01, SYSTXCCUID01-A, SYSTXCCUIZ01B, SYSTXCCUID01-V *** *** Factory New, Original Equipment OEM Carrier Products, Factory Warranty ***. Availability: Qty. 6 in stock for immediate shipment. SYSTXCCITC01-C, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B Infinity® System Control ... has been no interaction with the Infinity System Control for at least two Carrier Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs.Here's the equipment: Carrier 59MN7B060V17--14 60,000 BTU furnace, Infinity series. Carrier 24ACC624A003 Single stage AC, Performance. Carrier CAPMP3017ALA 2.5 Ton Evaporator coil. Thermostat is Honeywell T6 Lyric. Here’s how he set the switches: SW1: S1-off S2-off S3-on 4-off 5-on 6-off 7-on 8-off. SW2:Looks like you have a 5 stage, or green speed unit. Your going to need a contractor. Sometimes I can have weird electrical harmonics throw a communication fault, and it will pass. Those codes back to back, mean: 1. You had an electrical problem in the outdoor unit. 2. The outdoor board is no longer operating for a myriad of reasons.Apr 9, 2018 · Infinity isn't a thermostat, it is a computer monitoring and control system. It will read and adjust all equipment that matches the infinity system. It could control your airflow, the dining, the ac and heat, of course, but it also can regulate humidity and a slew of other things gs... IF YOU HAVE THAT EQUIPMENT. SYSTXCCITC01-C The series C software is available by Over The Air (OTA) only. Note: This software is for the Series C controls only. The Series A or B controls cannot useCarrier Infinity - SYSTXCCITC01-B System Control NOTE: Infinity System Control compatible with Infinity rated indoor equipment only. The Infinity System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface.Apr 5, 2023 · Carrier Infinity Touch circus continues SYSTXCCITC01-B off calibration issue. Ok, I have had my share of fun with Carrier infinity touch thermostats but I had a call back on a touch B where the temperature is off by 4 degrees. I verified temps and the unit is indeed showing 4 degrees colder than room temp. Oct 25, 2021 · I have a SYSTXCCUID01-B Version 14 Carrier Infinity System Thermostat that is malfunctioning and read you recommended the SYSTXCCITC01-B as a compatible replacement from supplyhouse.com. My question i … read more Carrier 59MN7A060V171214. The furnace was installed in Nov 2020 and ran without any issues last winter and this summer a/c season. Filters were changed every 3 months and a new one went in when the 126 code showed up a couple weeks ago at the start of this heating season but the 126 code still shows up after the new filter going in (M1-1056 ...The Carrier Infinity SYSTXCCITC01-B is part of the Thermostats test program at Consumer Reports. In our lab tests, Smart Thermostats models like the Infinity SYSTXCCITC01-B are rated... Carrier® Infinity® - SYSTXCCITC01-B System Control NOTE: Infinity® System Control compatible with Infinity® rated indoor equipment only. The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs.Oct 6, 2020 · Hello I have a Carrier infinity syetem with a SYSTXCCITC01-B thermostat. I have been trying to figure out how to have the humidifier on in manual or fan only mode. I can get it to turn on in the cool and heat profiles but cant get it to come on when I just want the fan on without heat or cool. The reason I want this is because I dont need heat ... Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings and cautions included in literature and attached to the unit. Consult local building codes and the current edition of the National Electrical Code (NEC) NFPA 70. In Canada, refer to the current editions of the Canadian Electrical Code CSA C22.1.Carrier SYSTXCCITC01-B Installation Instructions. Rating 2.5 (votes: 4) Description. Infinity isn't a thermostat, it is a computer monitoring and control system. It will read and adjust all equipment that matches the infinity system. It could control your airflow, the dining, the ac and heat, of course, but it also can regulate humidity and a slew of other things gs... IF YOU HAVE THAT EQUIPMENT.I have a carrier thermostat systxccitc01-b and it suddenly won't connect to my Orbi Router. The strange thing is it worked fine for almost a year. I found another thread to change the following CTS/RTS Threshold to 2347 and that didn't fix it. I turned off the AX for 2.4GHz and that didn't fix it. RBR850 / RBS850 Firmware Version 4.6.14.3Manuals and User Guides for Carrier Infinity SYSTXCCITC01-B. We have 4 Carrier Infinity SYSTXCCITC01-B manuals available for free PDF download: Installation Instructions Manual, Owner's Manual, Support Sheet.Wi-Fi ® enabled smart thermostats give you control over your home comfort. Using iOS ® or Android ® devices, you can adjust temperature, humidity, airflow, and ventilation from anywhere in the world. Add features like SmartSensors, voice control with Alexa ®, streaming music, or even hands-free calling to further enhance your smart home ...These systems have a feature called TrueSense filt er detection. This feature reads the change in static pressure caused by the filter accumulating di rt. At 1:00 pm each day the system will take a reading and record the change in static pressure. The clean or replace filter message will pop up when the filter is full. Carrier SYSTXCCITC01-B - Infinity System Control - 7 Day Programmable w/ Touch-N-Go- <b>Note: This item requires a "G" terminal that was not available on units prior to 2008 Infinity Models.</b><br><br> The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy ...Our ten year-old Infinity SYSTXCC Controller (for running a dual stage Heat Pump/Furnace system) has failed, and according to our service guy, it cannot be repaired. In 2008 when we bought it, the warranty was a measly 5 years with no option to extend it via registration. Carrier won't do anything for us, so we're SOL.Apr 13, 2023 · The evaporator coil had been replace in 11/22 and this issue started 2/23 so i don’t thing anything could have caused a problem when the coil was replaced. When I ran the new wire to the infinity control and left off the Wi-Fi for 3-4 months the customer didn’t call with any issues or just ignored them. Nov 11, 2022 · 8 Post Likes Carrier Thermostat SYSTXCCITC01-B vs SYSTXCCITC01-C Does anyone know the difference between these two models for Carrier's Infinity controlling thermostat? It seems that Carrier updated the model from B to C, but I do not see a chart or description anywhere of the differences between the two if any. Reply 11-11-2022, 07:02 PM #2 2sac Jun 25, 2022 · A few minutes later the system shut down again and again restarted. This happened a total of three times in one hour. I finally went to bed and it seemed to run ok during the night. I looked for a fault code in the thermostat log, and there was a UI - 160 humidity sensor fault but it was a week old. Carrier® Infinity® - SYSTXCCITC01-B System Control NOTE: Infinity® System Control compatible with Infinity® rated indoor equipment only. The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface.Carrier SYSTXCCITC01-B - Infinity System Control - 7 Day Programmable w/ Touch-N-Go- <b>Note: This item requires a "G" terminal that was not available on units prior to 2008 Infinity Models.</b><br><br> The Infinity® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy ... • When you have completed all of the settings touch SAVE. 3.1.2. Setup Time Zone The time zone can be selected by selecting the set time zone from the menu. Then select the time zone for the location. Time zones for both US and Canada are included. 3.1.3. Enable Time Synchronization After setting up the time zone, the time synchronization can ...Carrier Infinity Touch circus continues SYSTXCCITC01-B off calibration issue. Ok, I have had my share of fun with Carrier infinity touch thermostats but I had a call back on a touch B where the temperature is off by 4 degrees. I verified temps and the unit is indeed showing 4 degrees colder than room temp.May 29, 2019 · I've learned it's better to ask first. Thanks very much for the reply! I can confirm that these controls are interchangeable. I've installed a Carrier Infinity Touch SYSTXCCITC01-B with a Carrier FE4AN Fan Coil and a Bryant 280ANV Heat Pump and they all get along just fine. The primary cause has been corrected; but additional analysis is in progress to ensure this will not happen in the future. Minor updates: False G-terminal Alerts could be triggered during learning process check, if the system control reads the status inputs from furnace and fancoil before they have been set properly. Apr 5, 2023 · Carrier Infinity Touch circus continues SYSTXCCITC01-B off calibration issue. Ok, I have had my share of fun with Carrier infinity touch thermostats but I had a call back on a touch B where the temperature is off by 4 degrees. I verified temps and the unit is indeed showing 4 degrees colder than room temp. Carrier’s revolutionary Infinity ® System Control is the smart control of the future. Its unique system self--configuration and diagnostics capabilities make installation and service fast and accurate, helping to avoid costly call--backs. The Infinity ® System Control features a high resolution display, making it easier to read.Carrier’s revolutionary Infinity ® System Control is the smart control of the future. Its unique system self--configuration and diagnostics capabilities make installation and service fast and accurate, helping to avoid costly call--backs. The Infinity ® System Control features a high resolution display, making it easier to read.I have a three year old Carrier Infinity System Control Thermostat (SYSTXCCITC01-B) connected to a Carrier Furnace. The thermostat has stopped allowing me to use the schedule function. In addition, as far as I can tell, it has stopped allowing me to adjust the time. It does show the time which but it is off by one hour as it seems to think we ...SYSTXCCITC01-C, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B Infinity® System Control ... has been no interaction with the Infinity System Control for at least two Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs.Apr 9, 2018 · Infinity isn't a thermostat, it is a computer monitoring and control system. It will read and adjust all equipment that matches the infinity system. It could control your airflow, the dining, the ac and heat, of course, but it also can regulate humidity and a slew of other things gs... IF YOU HAVE THAT EQUIPMENT. • When you have completed all of the settings touch SAVE. 3.1.2. Setup Time Zone The time zone can be selected by selecting the set time zone from the menu. Then select the time zone for the location. Time zones for both US and Canada are included. 3.1.3. Enable Time Synchronization After setting up the time zone, the time synchronization can ...I have a three year old Carrier Infinity System Control Thermostat (SYSTXCCITC01-B) connected to a Carrier Furnace. The thermostat has stopped allowing me to use the schedule function. In addition, as far as I can tell, it has stopped allowing me to adjust the time. It does show the time which but it is off by one hour as it seems to think we ...Carrier Infinity - SYSTXCCITC01-B System Control NOTE: Infinity System Control compatible with Infinity rated indoor equipment only. The Infinity System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface.View and Download Carrier Infinity SYSTXCCWIC01-B installation instructions manual online. Infinity SYSTXCCWIC01-B thermostat pdf manual download. Also for: Infinity systxccitc01-b, Infinity systxccicf01-b, Infinity systxccwif01-b, A170203, A180218c.Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs.SYSTXCCITC01---B, SYSTXCCWIC01---B, SYSTXCCICF01---B, SYSTXCCWIF01---B Infinityr System Control Owner’s Manual A170203 A180218C NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Regards Teddy Bear. Bear Rules: Keep our home <50% RH summer, controls mites/mold and very comfortable. Provide 60-100 cfm of fresh air when occupied to purge indoor pollutants and keep window dry during cold weather. T-stat setup/setback +8 hrs. saves energy. Use +Merv 10 air filter. -Don't forget the "Golden Rule".Looks like you have a 5 stage, or green speed unit. Your going to need a contractor. Sometimes I can have weird electrical harmonics throw a communication fault, and it will pass. Those codes back to back, mean: 1. You had an electrical problem in the outdoor unit. 2. The outdoor board is no longer operating for a myriad of reasons.–Use the Up (Y) and Down (B) buttons to set the desired ventilation level. –Press SAVE when finished, or CANCEL to discard any changes. •If applicable, next select the amount of fresh air to circulate during cooling mode by touching COOLING FRESH AIR. Again, you will have the option of choosing among AUTO, MANUAL and OFF. Your Savings: $1,479.88 (52%) Carrier Products SYSTXCCITC01-B Infinity WiFi Touch Screen *** This Item is a direct current replacement for SYSTXCCUID01, SYSTXCCUID01-A, SYSTXCCUIZ01B, SYSTXCCUID01-V *** *** Factory New, Original Equipment OEM Carrier Products, Factory Warranty ***. Availability: Qty. 6 in stock for immediate shipment.Infinity ® System Control - SYSTXCCITC01-B. The Infinity ® System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. With wireless connectivity, occupancy sensing capabilities and built-in smarts, the Infinity System Control puts you in command of comfort and energy ... Mar 18, 2012 · T. The Raddish Discussion starter · Mar 18, 2012. I have a Carrier Infinity HVAC system, and this evening the thermostat lost power. I used my google prowess and found this, so this evening I crawled up in the attic and removed both panels. The 3 amp fuse is good, but there is an amber LED next to the fuse that is lit. Oct 6, 2020 · Hello I have a Carrier infinity syetem with a SYSTXCCITC01-B thermostat. I have been trying to figure out how to have the humidifier on in manual or fan only mode. I can get it to turn on in the cool and heat profiles but cant get it to come on when I just want the fan on without heat or cool. The reason I want this is because I dont need heat ... Carrier 59MN7A060V171214. The furnace was installed in Nov 2020 and ran without any issues last winter and this summer a/c season. Filters were changed every 3 months and a new one went in when the 126 code showed up a couple weeks ago at the start of this heating season but the 126 code still shows up after the new filter going in (M1-1056 ...Côr ® Wi-Fi ® Thermostat - TP-WEM01-A. Your heating and cooling system is where you spend most of your energy dollars so saving on your utilities is important. The innovative Côr ® thermostat has been Energy Star ® certified and is designed to combine home comfort with reduced energy use; homeowners saved an average of 20% on their heating and cooling energy costs. I've learned it's better to ask first. Thanks very much for the reply! I can confirm that these controls are interchangeable. I've installed a Carrier Infinity Touch SYSTXCCITC01-B with a Carrier FE4AN Fan Coil and a Bryant 280ANV Heat Pump and they all get along just fine.SYSTXCCITC01-B, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B ... The information displayed on the Home Screen will appear when there has been no interaction Feb 17, 2019 · Yes, using systxccitc01-b + Infinitude + the custom HA climate component, and the integration works. Only thing of note is that adjustments made on the thermostat itself occasionally get overwritten by Infinitude, so my family uses exclusively HA or Google home to make adjustments now, which is better than the interface on that POS anyhow. Mar 18, 2012 · T. The Raddish Discussion starter · Mar 18, 2012. I have a Carrier Infinity HVAC system, and this evening the thermostat lost power. I used my google prowess and found this, so this evening I crawled up in the attic and removed both panels. The 3 amp fuse is good, but there is an amber LED next to the fuse that is lit. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings and cautions included in literature and attached to the unit. Consult local building codes and the current edition of the National Electrical Code (NEC) NFPA 70. In Canada, refer to the current editions of the Canadian Electrical Code CSA C22.1. There is a ton of info in the Internet on how to access Diagnostic Mode on the old Carrier Infinity control Thermostat that uses buttons. I am not allowed to link to it but even Hunker, for example, has an article on how to do this. How do you enter diagnostic mode on the newer touch screen model (SYSTXCCITC01-B)? Can’t find this in any ...SYSTXCCICF01---B, SYSTXCCWIF01---B Infinityr System Control Owner’s Manual A170203 A180218C NOTE: Read the entire instruction manual before starting the installation. The features and functions outlined in this Owner’s Manual reflect Version 1.3 or later software. Occupancy sensing is only available with Series B Infinity System Controls.Carrier Infinity - SYSTXCCITC01-B System Control NOTE: Infinity System Control compatible with Infinity rated indoor equipment only. The Infinity System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface.

Infinity System Compatible Designed exclusively for our Infinity ® system products. This control is required to utilize all features of an Infinity system. Energy-Saving Intelligence Provides real-time energy use tracking. The system will also automatically and continuously adjust itself for advanced energy-savings performance. Remote Access. Vars

systxccitc01 b has been discontinued

I'm a newbie to this site. I've the latest Carrier Infinity WiFi thermostat SYSTXCCITC01-B installed in March of this year. I'm having trouble with connection to the Myinfinity server. My wifi connection is fine and it works with everything else in the house with the exception of the intermittent connection with the MyInfinity server.I've been looking to "upgrade" to the SYSTXCCITC01 thermostats to give remote access and smart home controls, but I am trying to determine what the difference between the A and B revisions are. The company that installed my Infinity system is quoting me to install the new thermostat, but list the A revision as the model.Carrier’s revolutionary Infinity ® System Control is the smart control of the future. Its unique system self--configuration and diagnostics capabilities make installation and service fast and accurate, helping to avoid costly call--backs. The Infinity ® System Control features a high resolution display, making it easier to read. SYSTXCCITC01-C, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B Infinity® System Control ... has been no interaction with the Infinity System Control for at least two Carrier Infinity - SYSTXCCITC01-B System Control NOTE: Infinity System Control compatible with Infinity rated indoor equipment only. The Infinity System Control is designed for homeowners who understand the value of precision comfort and an easy to use, intuitive user interface. I have a three year old Carrier Infinity System Control Thermostat (SYSTXCCITC01-B) connected to a Carrier Furnace. The thermostat has stopped allowing me to use the schedule function. In addition, as far as I can tell, it has stopped allowing me to adjust the time. It does show the time which but it is off by one hour as it seems to think we ...SYSTXCCITC01-C, SYSTXCCWIC01-B, SYSTXCCICF01-B, SYSTXCCWIF01-B: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 Model Number Nomenclature A170101 Fig. 1 – Unit Dimensions SYSTX Product Type Infinity® System ITC 01 Brand / Product CC = Carrier XX or NN ... (Models: SYSTXCCITW01-A, SYSTXCCINTN01-A, SYSTXCCITC01-A, SYSTXCCITC01-B, SYSTXCCWIC01-B) Daikin (Models: Daikin One) Daikin/Honeywell (Models: CTKO4, THX9001R5029) Ecobee (Models: Ecobee 3 Lite, Ecobee 4, Ecobee 5, Ecobee 6 Enhanced, Ecobee 6 Prem ium) Honeywell Prestige (Models: Prestige IAQ, Wi-Fi 9000) Honeywell T6 Pro The Carrier Infinity SYSTXCCITC01-B is part of the Thermostats test program at Consumer Reports. In our lab tests, Smart Thermostats models like the Infinity SYSTXCCITC01-B are rated... Control Unit Carrier Infinity SYSTXCCSAM01 Installation Instructions Manual. System access module (6 pages) Control Unit Carrier 42BJ ICM Installation Manual. Individual comfort module for variable air flow systems (44 pages) Control Unit Carrier 50CO Series Installation, Operation And Maintenance Instructions. Precision cabinet (32 pages)Yes, I have not been able to connect to my WiFi 6 access points running both 2.4g and 5g bands. All devices in home work fine except the Carrier thermostat. It worked with the Carrier ver 3.61 software, but stopped communicating on any version beyond 3.61. I had to downgrade from 4.05 to 3.61 for the thermostat to work correctly.Yes, I have not been able to connect to my WiFi 6 access points running both 2.4g and 5g bands. All devices in home work fine except the Carrier thermostat. It worked with the Carrier ver 3.61 software, but stopped communicating on any version beyond 3.61. I had to downgrade from 4.05 to 3.61 for the thermostat to work correctly. Dec 10, 2018 · I'm a newbie to this site. I've the latest Carrier Infinity WiFi thermostat SYSTXCCITC01-B installed in March of this year. I'm having trouble with connection to the Myinfinity server. My wifi connection is fine and it works with everything else in the house with the exception of the intermittent connection with the MyInfinity server. Taking your comfort well beyond temperature control, the Infinity System Control can manage humidity levels, airflow, ventilation, indoor air quality and up to 8 zones, from wherever you are, with a connected smartphone or tablet. It's also compatible with Amazon™ Alexa™. Energy-conscious homeowners will especially appreciate the energy ... .